Glucometer Strips "OG-CARE"

  • Glucometer Strips "OG-CARE"

 Click on an image to open Gallery

Brand:
Product Code:
01.04.1234
  • Call for price

Glucometer Strips "OG-CARE" 50 pieces.

Suitable for self-testing Product name OGCare Blood Glucose Test Strip Contents of the pack OGCare Reactive strips in the capped vial and instruction for use.

Intended Use. Test strips are to be used with OGCare Blood Glucose Meter, to monitor glucose concentration of capillary blood.

Application Scope. Test strips are for in-vitro diagnostic use and for self-testing, result should only be used for monitoring, not as diagnostic tools.

Testing Principles. The test strip measures glucose concentration in blood sample by measuring current produced by glucose oxidase solidified on test strip. The System is plasma-calibrated to allow easy comparison of results with laboratory methods, in the line with the recommendations of the International Federation of Clinical Chemistry and Laboratory Medicine(IFCC). This method is traceable to an NIST standard. If you have previously used whole-blood referenced test strips, your meter has been showing results that reflect blood glucose concentrations in whole blood. Blood glucose results from test strips that are plasma-referenced are approximately 11% higher than those obtained with whole-blood referenced test strips.

Major Components Each Test strip contains: Glucose oxidase (A.Niger) ..................................... 2.5unit Redox mediator ..................................... 32.3ug Buffer & Non-reactant ..................................... 50.5ug

Storage Condition. Test strips should be stored in the original strip vial and be located where is cool and dry at 4~30°C (39.2~86℉), and must not be frozen.

Expiration Date. Discard any remaining test strips 3 months after first opening the vial. Expiration date is printed on the packing box and the strip vial. Test Sample References Fresh whole blood from capillary vessel.

Non-Diabetics Reference Value Normal blood glucose reference value for non-diabetics are as follow:

- Before eating: 70 ~ 110mg/dL (3.9 ~ 6.1mmol/L)

- 2 hours after meal: Less than 140mg/dL (7.8mmol/L)

- In case results are out of reference range, please contact your healthcare professional and follow his advice

Specification:

  • Testing Range : 20 ~ 600mg/dL (1.1 ~ 33.3mmol/L).
  • Sample Volume : 0.5 ㎕.
  • Operating Temperature : (10~40℃) 50 ~ 104℉.
  • Operating Humidity : 10 ~ 90%RH.
  • Permissible Hematocrit Range : 20 ~ 60% 

     